Compressed natural gas cylinders on vehicles are built for a fixed life and a schedule of inspections, and both are written on the cylinder. When a CNG cylinder ruptures or leaks, those markings, the inspection history and the condition of the installation usually decide the case before anyone discusses design.
1. The label: standard, service life and expiration date
Vehicle CNG cylinders in the United States are built to FMVSS No. 304 or ANSI NGV 2, and NFPA 52 accepts either. Each cylinder carries a label with a “Do not use after” date. Depending on construction and certification, the useful life is typically 15, 20 or 25 years, and a cylinder past that date, or condemned at inspection, must be removed from service and destroyed. The owner is responsible for tracking that date. The first question in any case is whether the cylinder was still within its life.
2. The inspection history
The FMVSS 304 label also states when the cylinder must be visually inspected: after a motor vehicle accident or fire, and at least every 36 months or 36,000 miles on vehicles of 4,536 kg (10,000 lb) gross weight or less, or at least every 12 months on heavier vehicles, under the version of the rule in force since 2022. Inspection records, or their absence, show whether damage should have been found. Inspections are expected to follow industry practice such as CGA C-6.4 and be done by trained inspectors.
3. The installation
Many CNG cylinder problems start with how the cylinder was mounted and protected: brackets and straps, rubbing points, shields, exposure to road debris and to chemicals such as battery acid, and the routing of vent lines from the pressure relief devices. Photograph and preserve the brackets, straps and fittings along with the cylinder.
4. Damage, heat and fire
Cuts, abrasion, impacts and chemical attack on the overwrap leave evidence that a trained inspector should have seen, and they change the strength of the cylinder over time. In a fire, the question is whether the thermally activated relief device vented as designed. A fire that heats part of a cylinder away from the device is the hardest case, as our article on hydrogen tank failures explains; the same physics applies to CNG.
5. The fueling history
Dispenser records and fueling station data matter too. The NREL guidance for CNG safety calls for inspection after a dispenser malfunction that overpressurizes a cylinder above 125 percent of its service pressure. Overfilling and repeated overpressure point away from the cylinder maker and toward the station or the operator.
Investigating a cylinder failure?
Contact us before any destructive examination or testing. We can help agree an inspection protocol, preserve the evidence and scope the failure analysis.
This is general technical guidance, not legal advice. Every matter depends on its own facts and evidence.